Project/Building

Building Designer

1–20 storey framed buildings · RC or steel · gravity, wind and seismic · foundations and quantities

Presets
Structure and geometry
Use and loads

For a full layout with real doors and windows use the Walls, Doors & Windows tool.

Materials
Lateral loads
Shear walls / cores

Walls share the lateral load with the frames by stiffness. Set the count to 0 for a frame-only building.

Foundation and code
All checks pass · 4 storeys · H = 13.2 m · plan 18.0 × 12.0 m · floor area 864 m²
Critical 2D frame method: torsion, 3D effects, diaphragm flexibility and foundation interaction are not modelled. Verify with a full 3D model for final design.

Summary of checks

  • OKSlab 220 mm, two-way panel 6 × 6 m
  • OKBeams 350 × 400 mm, 0 of 12 failing
  • OKColumns 0 of 4 storeys failing
  • OKDrift: Wind (SLS, limit h/500) max drift 0.05% of storey height
  • OKP-Δ sensitivity θ (Wind) max θ = 0.047 (limit 0.1)
  • OKRoof sway (wind) ≤ H/500 5.3 ≤ 26 mm
  • OKFooting: Edge column (critical frame) 1.8 × 1.8 m, h = 400 mm, NEd = 600 kN
  • OKFooting: Interior column (critical frame) 2.3 × 2.3 m, h = 450 mm, NEd = 1270 kN
  • OKConcrete class for frame (XC1) C30 ≥ C20/25; limits w/c ≤ 0.65, cement ≥ 260 kg/m³
  • OKConcrete class for foundations (XC2) C30 ≥ C25/30; limits w/c ≤ 0.6, cement ≥ 280 kg/m³
  • OKFire R60: slab axis distance 29 mm ≥ 20 mm required for 220 mm section
  • OKFire R60: beams axis distance 41 mm ≥ 25 mm required for 350 mm section
  • OKFire R60: columns axis distance 48 mm ≥ 40 mm required for 350 mm section
  • OKRaft: eccentricity (no uplift) e = 0.06 m ≤ L/6 = 3.33 m
  • OKRaft: bearing pressure q,max = 50 kPa ≤ 200 kPa
  • OKRaft: overturning 0.9GL/2 / M = 130.09 (≥ 1.5)
  • OKRaft: sliding μ·0.9G / H = 42.19 (≥ 1.0)
  • OKRaft slab: punching and flexure 500 mm thick, bottom Ø12@125, top Ø10@100 each way
Floor slab (typical critical panel)
Thickness / type220 mm, two-way
ULS floor load / roof load13.13 / 10.35 kN/m²
Bottom steel (short span)Ø8 @ 150 mm
Bottom steel (long span / distribution)Ø8 @ 175 mm
Beams: 350 × 400 mm throughout (governing beam per storey)
StoreySpanM sagM hogVBottomTopLinks
46.0 m821401395Ø125Ø16Ø8@250OK
36.0 m931681684Ø164Ø20Ø8@200OK
26.0 m931761694Ø165Ø20Ø8@200OK
16.0 m971871724Ø165Ø20Ø8@200OK

Moments in kNm, shear in kN, from the envelope of all load cases on the critical frame. Reinforcement is for the governing beam of each storey; other beams are detailed from the same analysis.

Columns (per storey, worst column governs)
StoreySizeNEd (kN)M (kNm)BarsρLinks
4350 × 350269914Ø201.03%Ø8@350OK
3350 × 350602716Ø120.55%Ø8@225OK
2350 × 350935824Ø120.37%Ø8@225OK
1350 × 3501270634Ø120.37%Ø8@225OK
Floor-by-floor schedule
FloorLevel (m)g / q (kN/m²)SlabBeamsBeam Msag / Mhog / VBeam barsColumnN / M (kN, kNm)Column barsWind / seismic F (kN)Drift (‰)
Roof13.27.0 / 0.6220 mm
Ø8@150 + top Ø8@150
350 × 40082 / 140 / 139bot 5Ø12
top 5Ø16
links Ø8@250
350 × 350269 / 914Ø20
links Ø8@350
18 / —0.2 (≤ 2.0)OK
Level 210.07.5 / 2.0220 mm
Ø8@150 + top Ø8@150
350 × 40093 / 168 / 168bot 4Ø16
top 4Ø20
links Ø8@200
350 × 350602 / 716Ø12
links Ø8@225
33 / —0.3 (≤ 2.0)OK
Level 16.87.5 / 2.0220 mm
Ø8@150 + top Ø8@150
350 × 40093 / 176 / 169bot 4Ø16
top 5Ø20
links Ø8@200
350 × 350935 / 824Ø12
links Ø8@225
28 / —0.5 (≤ 2.0)OK
Ground floor3.67.5 / 2.0220 mm
Ø8@150 + top Ø8@150
350 × 40097 / 187 / 172bot 4Ø16
top 5Ø20
links Ø8@200
350 × 3501270 / 634Ø12
links Ø8@225
26 / —0.5 (≤ 2.0)OK

Beam and column sizes are uniform per storey; bars are the governing member of each storey. Slab steel is for the critical panel.

Foundations (pad footings, critical frame)
ColumnNEdMEdSizeDepthBars (each way)
Edge column (critical frame)600 kN51 kNm1.8 × 1.8 m400 mmØ10@150OK
Interior column (critical frame)1270 kN32 kNm2.3 × 2.3 m450 mmØ10@100OK
Whole-building raft (stability)
Raft plan (building + 1.0 m all round)20.0 × 14.0 m, 500 mm thick (designed)
Permanent load G / variable Q12440 / 1426 kN
Overturning moment (wind) / base shear861 kNm / 106 kN
Eccentricity e (limit L/6)0.06 m (3.33 m)
Bearing pressure max / min (allowable)50 / 49 kPa (200)
Net ULS pressure under heaviest column panel35 kPa
Effective depth d434 mm
Bottom bars (each way)Ø12 @ 125 mm
Top bars (each way)Ø10 @ 100 mm
Reinforcement27 kg/m²
Raft quantities (alternative to the pads)140 m³ concrete, 7430 kg steel

✓ Raft slab: punching and flexure

✓ Raft: eccentricity (no uplift): e = 0.06 m ≤ L/6 = 3.33 m

✓ Raft: bearing pressure: q,max = 50 kPa ≤ 200 kPa

✓ Raft: overturning: 0.9GL/2 / M = 130.09 (≥ 1.5)

✓ Raft: sliding: μ·0.9G / H = 42.19 (≥ 1.0)

Rigid-raft assumption, friction μ = 0.4, characteristic loads. The slab is sized as an inverted flat slab under the heaviest column (punching, shear, flexure; top steel for the span moment). It does not model soil-structure interaction: confirm with a raft or finite-element analysis.

Lateral loads and stability
Wind base shear (whole building)106 kN
Roof sway (SLS wind)5.3 mm (limit 26 mm)

Wind (SLS, limit h/500)

StoreyDrift (mm)Limit (mm)θ
40.66.40.022OK
31.16.40.030OK
21.76.40.047OK
11.87.20.045OK
Quantities (estimate)
Concrete: slabs / beams / columns / footings190 / 26 / 19 / 18 m³
Concrete total253 m³
Reinforcement total14.2 t
Steel per m³ concrete56 kg/m³
Steel per m² floor16.5 kg/m²

Preliminary quantities only: rebar excludes laps, wastage, stirrup hooks detail and non-critical members beyond the intensity extrapolated from the designed frame.

Scope: regular rectangular frame, critical 2D frame method (equal lateral share between frames), diaphragm assumed rigid, T-beam flange action ignored in beams, no shear walls or cores (use the Lateral tool for walls), pad footings on uniform soil, no basement or retaining walls. Results are an aid only and must be verified by a qualified, licensed engineer before use. National Annex presets are recommended values and must be checked against the official documents.