Building Designer
1–20 storey framed buildings · RC or steel · gravity, wind and seismic · foundations and quantities
For a full layout with real doors and windows use the Walls, Doors & Windows tool.
Walls share the lateral load with the frames by stiffness. Set the count to 0 for a frame-only building.
Summary of checks
- OKSlab 220 mm, two-way panel 6 × 6 m
- OKBeams 350 × 400 mm, 0 of 12 failing
- OKColumns 0 of 4 storeys failing
- OKDrift: Wind (SLS, limit h/500) max drift 0.05% of storey height
- OKP-Δ sensitivity θ (Wind) max θ = 0.047 (limit 0.1)
- OKRoof sway (wind) ≤ H/500 5.3 ≤ 26 mm
- OKFooting: Edge column (critical frame) 1.8 × 1.8 m, h = 400 mm, NEd = 600 kN
- OKFooting: Interior column (critical frame) 2.3 × 2.3 m, h = 450 mm, NEd = 1270 kN
- OKConcrete class for frame (XC1) C30 ≥ C20/25; limits w/c ≤ 0.65, cement ≥ 260 kg/m³
- OKConcrete class for foundations (XC2) C30 ≥ C25/30; limits w/c ≤ 0.6, cement ≥ 280 kg/m³
- OKFire R60: slab axis distance 29 mm ≥ 20 mm required for 220 mm section
- OKFire R60: beams axis distance 41 mm ≥ 25 mm required for 350 mm section
- OKFire R60: columns axis distance 48 mm ≥ 40 mm required for 350 mm section
- OKRaft: eccentricity (no uplift) e = 0.06 m ≤ L/6 = 3.33 m
- OKRaft: bearing pressure q,max = 50 kPa ≤ 200 kPa
- OKRaft: overturning 0.9GL/2 / M = 130.09 (≥ 1.5)
- OKRaft: sliding μ·0.9G / H = 42.19 (≥ 1.0)
- OKRaft slab: punching and flexure 500 mm thick, bottom Ø12@125, top Ø10@100 each way
| Thickness / type | 220 mm, two-way | |
| ULS floor load / roof load | 13.13 / 10.35 kN/m² | |
| Bottom steel (short span) | Ø8 @ 150 mm | |
| Bottom steel (long span / distribution) | Ø8 @ 175 mm |
| Storey | Span | M sag | M hog | V | Bottom | Top | Links | |
|---|---|---|---|---|---|---|---|---|
| 4 | 6.0 m | 82 | 140 | 139 | 5Ø12 | 5Ø16 | Ø8@250 | OK |
| 3 | 6.0 m | 93 | 168 | 168 | 4Ø16 | 4Ø20 | Ø8@200 | OK |
| 2 | 6.0 m | 93 | 176 | 169 | 4Ø16 | 5Ø20 | Ø8@200 | OK |
| 1 | 6.0 m | 97 | 187 | 172 | 4Ø16 | 5Ø20 | Ø8@200 | OK |
Moments in kNm, shear in kN, from the envelope of all load cases on the critical frame. Reinforcement is for the governing beam of each storey; other beams are detailed from the same analysis.
| Storey | Size | NEd (kN) | M (kNm) | Bars | ρ | Links | |
|---|---|---|---|---|---|---|---|
| 4 | 350 × 350 | 269 | 91 | 4Ø20 | 1.03% | Ø8@350 | OK |
| 3 | 350 × 350 | 602 | 71 | 6Ø12 | 0.55% | Ø8@225 | OK |
| 2 | 350 × 350 | 935 | 82 | 4Ø12 | 0.37% | Ø8@225 | OK |
| 1 | 350 × 350 | 1270 | 63 | 4Ø12 | 0.37% | Ø8@225 | OK |
| Floor | Level (m) | g / q (kN/m²) | Slab | Beams | Beam Msag / Mhog / V | Beam bars | Column | N / M (kN, kNm) | Column bars | Wind / seismic F (kN) | Drift (‰) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Roof | 13.2 | 7.0 / 0.6 | 220 mm Ø8@150 + top Ø8@150 | 350 × 400 | 82 / 140 / 139 | bot 5Ø12 top 5Ø16 links Ø8@250 | 350 × 350 | 269 / 91 | 4Ø20 links Ø8@350 | 18 / — | 0.2 (≤ 2.0) | OK |
| Level 2 | 10.0 | 7.5 / 2.0 | 220 mm Ø8@150 + top Ø8@150 | 350 × 400 | 93 / 168 / 168 | bot 4Ø16 top 4Ø20 links Ø8@200 | 350 × 350 | 602 / 71 | 6Ø12 links Ø8@225 | 33 / — | 0.3 (≤ 2.0) | OK |
| Level 1 | 6.8 | 7.5 / 2.0 | 220 mm Ø8@150 + top Ø8@150 | 350 × 400 | 93 / 176 / 169 | bot 4Ø16 top 5Ø20 links Ø8@200 | 350 × 350 | 935 / 82 | 4Ø12 links Ø8@225 | 28 / — | 0.5 (≤ 2.0) | OK |
| Ground floor | 3.6 | 7.5 / 2.0 | 220 mm Ø8@150 + top Ø8@150 | 350 × 400 | 97 / 187 / 172 | bot 4Ø16 top 5Ø20 links Ø8@200 | 350 × 350 | 1270 / 63 | 4Ø12 links Ø8@225 | 26 / — | 0.5 (≤ 2.0) | OK |
Beam and column sizes are uniform per storey; bars are the governing member of each storey. Slab steel is for the critical panel.
| Column | NEd | MEd | Size | Depth | Bars (each way) | |
|---|---|---|---|---|---|---|
| Edge column (critical frame) | 600 kN | 51 kNm | 1.8 × 1.8 m | 400 mm | Ø10@150 | OK |
| Interior column (critical frame) | 1270 kN | 32 kNm | 2.3 × 2.3 m | 450 mm | Ø10@100 | OK |
| Raft plan (building + 1.0 m all round) | 20.0 × 14.0 m, 500 mm thick (designed) | |
| Permanent load G / variable Q | 12440 / 1426 kN | |
| Overturning moment (wind) / base shear | 861 kNm / 106 kN | |
| Eccentricity e (limit L/6) | 0.06 m (3.33 m) | |
| Bearing pressure max / min (allowable) | 50 / 49 kPa (200) |
| Net ULS pressure under heaviest column panel | 35 kPa | |
| Effective depth d | 434 mm | |
| Bottom bars (each way) | Ø12 @ 125 mm | |
| Top bars (each way) | Ø10 @ 100 mm | |
| Reinforcement | 27 kg/m² | |
| Raft quantities (alternative to the pads) | 140 m³ concrete, 7430 kg steel |
✓ Raft slab: punching and flexure
✓ Raft: eccentricity (no uplift): e = 0.06 m ≤ L/6 = 3.33 m
✓ Raft: bearing pressure: q,max = 50 kPa ≤ 200 kPa
✓ Raft: overturning: 0.9GL/2 / M = 130.09 (≥ 1.5)
✓ Raft: sliding: μ·0.9G / H = 42.19 (≥ 1.0)
Rigid-raft assumption, friction μ = 0.4, characteristic loads. The slab is sized as an inverted flat slab under the heaviest column (punching, shear, flexure; top steel for the span moment). It does not model soil-structure interaction: confirm with a raft or finite-element analysis.
| Wind base shear (whole building) | 106 kN | |
| Roof sway (SLS wind) | 5.3 mm (limit 26 mm) |
Wind (SLS, limit h/500)
| Storey | Drift (mm) | Limit (mm) | θ | |
|---|---|---|---|---|
| 4 | 0.6 | 6.4 | 0.022 | OK |
| 3 | 1.1 | 6.4 | 0.030 | OK |
| 2 | 1.7 | 6.4 | 0.047 | OK |
| 1 | 1.8 | 7.2 | 0.045 | OK |
| Concrete: slabs / beams / columns / footings | 190 / 26 / 19 / 18 m³ | |
| Concrete total | 253 m³ | |
| Reinforcement total | 14.2 t | |
| Steel per m³ concrete | 56 kg/m³ | |
| Steel per m² floor | 16.5 kg/m² |
Preliminary quantities only: rebar excludes laps, wastage, stirrup hooks detail and non-critical members beyond the intensity extrapolated from the designed frame.
Scope: regular rectangular frame, critical 2D frame method (equal lateral share between frames), diaphragm assumed rigid, T-beam flange action ignored in beams, no shear walls or cores (use the Lateral tool for walls), pad footings on uniform soil, no basement or retaining walls. Results are an aid only and must be verified by a qualified, licensed engineer before use. National Annex presets are recommended values and must be checked against the official documents.